ENGINEERED FOR HEAVY LOADS From the Netherlands. Delivered worldwide.A STARKON company

TECHNICAL CONFIDENCE

DEFINED LOADS.
DOCUMENTED SUPPORT.

A tonne rating is meaningful when the load case, contact area and support conditions are defined. That is where our engineering approach starts.

Four load cases.
One clear language.

Our standard selection tables distinguish a full circular contact area, a half-area contact and two 300 mm strip-load cases. Loads outside the illustrated area or concentrated forces need a separate review.

CASE A
200 tFull circular area
CASE B
75 tHalf circular area
CASE C
60 t300 mm central strip
CASE D
30 tHalf-length central strip

Capacities are stated per stool for the illustrated static load case. Proposed ratings are subject to final engineering verification and release before supply. The base must be fully supported on a level, sufficiently stiff surface. Published average ground pressure is a planning value, not the maximum local contact pressure.

DESIGN & FABRICATION BASIS

Standards with a purpose.

The STSS design framework uses structural steel principles. The applicable editions, national annexes and project requirements are confirmed for the final engineering dossier.

EN 1990

Basis of structural design

Reliability, limit states and combinations of actions form the starting point for the structural assessment.

European Commission reference
EN 1993

Design of steel structures

Relevant Eurocode 3 provisions address steel members, stability, shells and connections, including welded and bolted joints.

Eurocode 3 reference
EN 1090-2

Execution of steelwork

The intended fabrication basis covers technical execution requirements. Welding, tolerances and inspection are specified for the agreed product.

NEN standard reference

These are the selected engineering and intended fabrication bases, not a statement of completed certification. Documentation and release are confirmed for the agreed supply. CE applicability is assessed for the intended product use; citing EN 1090-2 alone does not establish a CE marking basis.

CLEAR DOCUMENTATION

Know what you’re
putting under the load.

Technical data before you enquire

Each product page provides its model reference, overall dimensions, indicative self-weight and load-case table. Download the English product sheet and include the model in your quote request.

Application-specific information at supply

The agreed scope defines final capacity markings, operating instructions, inspection requirements and the relevant manufacturing and engineering records.

Explore technical product data
YOUR NEXT HEAVY LOAD

Let’s put it on
solid ground.

Configure your support